WebMar 28, 2015 · CODE: SNS PROBLEM: Temperature sensor is out of acceptable range. FIX: 1. Water temperature is below 36F or above 110F 2. If the two thermistors are more than 2 … WebMar 20, 2011 · Raypak heater 2100 model 185A getting sns code/ replaced the raypak heater 2100 model 185A getting sns code/ replaced the sensor, same code, heater does …
Quick Reference Guide - JustAnswer
WebMay 7, 2024 · Temperature sensor is out of acceptable range. 1. Water temperature is below 36F or above 110F. 2. If the two thermistors are more than 2 degrees apart, the SNS code will appear. 3. Loose or corroded connection at P1. 4. If the sensor is not mounted all the way into the JACO fitting on the header, it may give a false reading. http://www.poolforum.com/pf2/showthread.php/9046-Raypak-RP2100-SNS-code-need-help graphic design graduate programs
Raypak Heater won
WebMay 23, 2024 · FL. May 22, 2024. #2. Not at all difficult to replace. You'll remove the front door, the four screws holding the panel with the board, and the top side panel where the sensor is located. Unscrew the white nut holding sensor in and then go from there. Assuming it is the temp sensor. WebI am replacing my old Anthony (Citadel) heater with a RayPak Digital 333,000 BTU Natural Gas Pool Heater model P-R336A-EN-X. The RayPak Installation manual says it is compatible with most 2 & 3 wire c … read more WebMay 1, 2024 · FL. Apr 29, 2024. #2. Take the heater out of "remote" mode and try it. Simultaneously hold down all three buttons to take it out of remote mode and then see if it fires. Make sure the temp is set to 104 for when you put it in remote mode. chirey car one